100% Fresh Air Heat Pump Packaged Rooftop Air Conditioner

100% Fresh Air Heat Pump Packaged Rooftop Air Conditioner

100% fresh air heat pump packaged rooftop air conditioner 1. Hotel air source heat pump 2. CE, RoHS approved 3. Easy ins
Basic Info.
Model NO. SLA60D
Mounting Floor Standing
Lifetime 15~20 years
Certification RoHS, ISO, CE
Condition New
Installation Freestanding
Refrigerant R417A/R407c/R404A/R410A/R22/R134A
Use Swimming Pool Heater
Storage / Tankless Instant / Tankless
Housing Materia Stainless Steel, Coated Metal
Name 100% Fresh Air Heat Pump Packaged Rooftop Air Cond
Transport Package Customerized Packingfor Hotel Air Source Heat Pump
Specification CE, RoHS
Trademark Shenglin
Origin China Mainland
HS Code 35324169
Production Capacity 2000
Product Description
100% fresh air heat pump packaged rooftop air conditioner
1. Hotel air source heat pump
2. CE, RoHS approved
3. Easy installation and maintenence
4. High efficiency
5. Low noise level
Shanghai Shenglin provides customers with high-quality and high-effect products based on advanced production technologies, mature manufacturing processes and strict quality controls and keep communicating with understanding customers demands, which repays us with self improvements and the trust and recognition of customers
Hotel air source heat pump:
1. Economical operation
Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.
2. Safety
Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated
3. Environmental friendly
Transfer heat that's already in the environment; Low CO2 emissions.
4. Easy operation
With intelligent control systems which convenient and simple operation
5. Constant hot water supply
Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.
6. Heat pump water heater can be applied to sanitary hot water, house heating.
Quality Control
NewTimes air to water heat pump water heater production quality control:
1. Research and Development
We have more than 30 well-qualified technology elites.
Our R&D team has many years experiences of heat pump, we We have been committed to improving the COP, technology, and defrosting items.
2. Purchasing
In order to ensure heat pump quality, we purchasing department purchase good quality materials according to each model heat pump BOM list.
We demand each spare parts supplier has products testing report, and relative CCC, ISO certificates, from compressor, expansion valve and so on core material to small parts such as screw, shim and so on. Our quality department strictly inspect on all materials.
3. Production
Each worker must operate seriously according to production operating standard, pay attention to each installation link, both copper pipe welding and electric controlling connection are both finished with professional technology. Each production line will be responsible for its procedure.
4. Checking
The quality department will check each procedure of heat pump. And each heat pump water heater must be checked seriously before leave our factory, COP, heating capacity must be reach national standard, all parameters such as current, pressure, and water temperature and so on must be recorded, each heat pump test report is stored.
5. Package
The qualified heat pump is packaged by especial designed cartoon or fumigation wooden frame before send to our warehouse, avoid hitting.
6. Services:
Supply OEM service for customers.
Produce heat pump according to customer's special demands.
Supply free spare parts according to order quantity.
Long warranty period.
We are Detail Oriented, Focus on Quality, Never Cut Corners'.

100% Fresh Air Heat Pump Packaged Rooftop Air Conditioner


100% Fresh Air Heat Pump Packaged Rooftop Air Conditioner


100% Fresh Air Heat Pump Packaged Rooftop Air Conditioner


100% Fresh Air Heat Pump Packaged Rooftop Air Conditioner


100% Fresh Air Heat Pump Packaged Rooftop Air Conditioner

ModelSLA20DSLA30DSLA50DSLA60DSLA100DSLA200DSLA300D
Input power (KW)1.82.94.45.48.817.621
Heating capacity (KW)7.5121922387688
Cooling capacity (KW)5.491417285665
Hot Water supply(L/H) 16028040050080016002000
Rated voltage (V)220220/380380380380380380
Rated frequency (HZ)50/60
Rated current (A)813/6912183540
Rated outlet water temp (°C)55
Outlet water Max temp (°C)60
Source side water flow L/H2000~24003600~40005500~65007000~800011000~1300022000~2600025000~30000
Hot water side water flow L/H2000360055007000110002200025000
Pipe SizeDN25DN25DN25DN32DN32DN50DN50
Dimension(mm)657*557*7801030*685*7201150*740*720
Packing dimensions (mm)730*630*9201100*755*8651230*820*865
Weight (KG) 88125170175360640660
Leve of securityIP×4
Electric shock protection grade1 Grade
Noise (Db)40 4550505555 55
RefrigerantR417A/R407C/R404A/R410A/R134A
CompressorPanasonicDanfoss
Condenser:Double pipe heat exchanger
Evaporator: Plate heat exchanger,
Throttle unit: "Emerson" Thermal expansion valve
Body: Spray coating.